ANSI A (), Standard for Accessible and Usable Buildings and Facilities as mandated by law and incorporated by reference by the States and. arrow_right. Access anywhere on computer, tablet, phone. arrow_right. Search content, annotate, bookmark, share. arrow_right. Powered by ICC. Learn More. The specifications in this standard make sites, facilities, buildings and elements accessible to and usable by people with such physical disabilities as the inability .

Author: Yolkree Murr
Country: Libya
Language: English (Spanish)
Genre: Business
Published (Last): 12 November 2004
Pages: 117
PDF File Size: 15.17 Mb
ePub File Size: 19.37 Mb
ISBN: 613-9-85827-673-2
Downloads: 39709
Price: Free* [*Free Regsitration Required]
Uploader: JoJogrel

Landings shall have a length of 60 inches mm minimum. Annsi and van parking spaces shall have an adjacent access aisle complying with Section Protruding objects shall not reduce the clear width required for accessi- ble routes. Doors and sidelites adja- cent to doors containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one panel on either the door or an adjacent sidelite 43 inches mm maximum above the floor.

As the voice of the U.

Lifts with ramps shall com- ply with Section Audible and visible car position indicators shall be provided in elevator cars. Objects on multiple posts or pylons where the clear distance between the posts or pylons is greater than 1 2 inches mm shall have the low- est edge of wnsi object either 27 inches mm maximum or 80 inches mm minimum above the floor.

Accessibility PocketBook: IBC : ICC/ANSI A –

Where parking spaces or access aisles are not adjacent to another parking space or access aisle, measurements shall be permit- ted to include the full width of the line defining the parking space or access aisle.

The clear- ance between the platform sill and the edge of any runway landing shall be 1V 4 inch 32 mm maxi- mum. In existing elevators, where a new car operating panel complying with Section Need more than one copy? The lower grab bar on the back wall of a bathtub required by Section Knee and toe space complying with Section shall be provided.

The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, paper dis- pensers, sanitary napkin receptacles, coat hooks, shelves, accessible routes, clear floor space at other fixtures and the turning space.

Walking ansk with a slope not steeper than 1: In a com- partment primarily for children’s use, greater than 65 inches mm in depth, toe clearance at the front partition is not required. Where receipts are provided, speech output devices shall provide audible bal- ance inquiry information, error messages, and all other information on the printed receipt neces- sary to complete or verify the transaction.

Pictograms shall contrast with their fields, with either a light pictogram on ani dark field or a dark pictogram on a light field. Transfer-type shower compartments shall have a clear inside dimension of 36 inches mm in width and 36 z117 mm in depth, measured at the center point of opposing sides.

The minimum, area of an ambula- tory accessible compartment shall be 60 inches 1 mm minimum in depth and 36 inches mm in width.

Table of Contents | ICC/ANSI A – | ICC premiumACCESS

The uppercase letter “I” shall be used to determine the allowable height of all characters of a font. When two or more columns of buttons are provided they shall read from left to right. Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route.

Signs identifying van parking spaces shall contain the designation “van accessible. Van parking spaces shall be inches mm minimum in width. Please first log in with a verified email before subscribing to alerts. Stair treads shall comply with Section and shall have a slope not steeper than 1: Its use within a governmental jurisdiction is intended to be accomplished through adoption by reference in accordance with proceedings establishing the jurisdiction’s laws.

Car and van park- ing spaces shall be marked to define the width. Controls shall comply with Sec- tion Park- ing spaces and access aisles shall be designed so that cars and vans, when parked, cannot obstruct the required clear width of adjacent accessible routes.

You need to upgrade your browser

Passenger loading zones shall have an adjacent access aisle complying with Section Tactile character stroke width shall comply with Section The uppercase letter “I” of the font shall be used to determine the allowable stroke width of all char- acters of a font. Detectable warning sur- faces in interior locations shall differ from adjoining walking ans in resiliency or sound-on-cane contact. Plumbing Elements and Aa117 The system shall provide both visual and audible signals.

Car doors shall provide a clear opening width of 32 inches mm minimum.

The front partition and at least one side partition shall provide a toe clearance of 9 inches mm minimum above the floor and extending 6 inches mm beyond the compartment side face of the parti- tion, znsi of partition support members.

The up scan button shall sequentially select floors above the current floor. Unless otherwise specified, doors aansi be permitted to swing into turning spaces. The front of lavatories and sinks shall be 34 inches mm maximum above the floor, measured to the higher of the rim or counter sur- face.

The edition largely achieved that goal.

2003 ICC Accessible and Usable Buildings and Facilities

Toe clearance at the side partition is not required in a compartment greater than 66 inches mm in width. Maneuver- ing clearances at power-assisted doors shall comply with Section Seats shall comply with Section ‘ Communications elements and fea- tures required to be accessible by the scoping provi- sions adopted by the administrative authority shall comply with the applicable provisions of Chapter 7.

Function key surfaces shall have asni tactile symbols as shown in Table Passenger loading zones shall provide a vehicular pull-up space 96 inches mm minimum in width and 20 feet mm minimum in length. The reopening device shall remain effective for 20 seconds minimum. February Fourth Printing: Where knee clear- ance is required beneath an element as part of a clear floor space, the knee clearance shall be 1 1 a Forward Approach b Parallel Qnsi Fig.

Openings in floor surfaces shall be of a size that does not permit the passage of a V 2 inch 13 mm diameter sphere, except as allowed in Sections